1.
China Journal of Orthopaedics and Traumatology ; (12): 524-530, 2019.
Article in Chinese | WPRIM | ID: wpr-773885

ABSTRACT

OBJECTIVE@#The 3D model of lumbar spine was established by using Mimics software. To observe the applicability and needling parameters of lumbar vertebral kyphoplasty with unilateral puncture by backward rotation method using simulated puncture.@*METHODS@#Twenty-four patients (12 males and 12 females) with osteoporotic thoracic fracture in the first time and no signs of lumbar misalignment and bone destruction were scanned by spiral CT on the lumbar spine. The original DICOM file was modeled in 3D with Mimics software, and the vertebral bodies were separated. After being imported into 3-matic software, the posterior wall of the vertebral body was restrained for standardized measurement. A sketch perpendicular to the mid-section of the pedicle and the posterior wall of the vertebral body was drawn. The simulated puncture was performed on the sketch. The angle and distance parameters of the range of motion of the puncture needle were recorded, and the puncture needle was recorded at the top. The crossing points of the anterior, middle and posterior zones of the tangential line of the vertebral body were located at the high extraversion angle, and the results were compared and analyzed.@*RESULTS@#All the data in the left and right sides had no significantly differences(>0.05). Data of different segments in different gender were significantly differences(<0.05). The maximal extraversion angle in lumbar spine increased gradually from (33.41±1.31) degree to (56.53±4.71) degree in males, as same as in females from(28.58±2.55) to (53.86±2.68) degree. There was no crossing point in area A, 3.3% of males and 26.67% of females in area B, rest in area C. The distribution areas on gender showed statistically significance (<0.05).@*CONCLUSIONS@#Backward rotation method can theoretically meet the requirements of puncture point for vertebral compression fracture, especially for males and lower lumbar spine. The determination of the maximum inclination angle is of guiding significance to the backward rotation method.


Subject(s)
Female , Humans , Male , Fractures, Compression , Kyphoplasty , Lumbar Vertebrae , Osteoporotic Fractures , Punctures , Rotation , Spinal Fractures , Thoracic Vertebrae , Treatment Outcome
2.
Chinese Journal of School Health ; (12): 1706-1708, 2019.
Article in Chinese | WPRIM | ID: wpr-815823

ABSTRACT

Objective@#To understand the microbial pollution of indoor air in colleges and universities, and to provide a reference for controlling microbial pollution and improving indoor air quality.@*Methods@#In November 2018, the air microorganisms in different functional areas and at different times were sampled and cultured in a university in Beijing by Anderson’s six-level sampler.@*Results@#During the test, there were differences in microbial aerosol concentrations in different functional areas and at different times(F=3.99,7.77, P<0.05), the concentration of bacteria in toilets was relatively high, the average concentration was 659 CFU/m3 and the concentration of fungi in the campus was relatively high, the average concentration was 660 CFU/m3; the concentration of bacteria and fungi in the air at 12 o’clock noon was relatively low, the average concentration was 320 CFU/m3 and 322 CFU/m3. The particle size distribution of microorganisms in the air presents roughly the same law, and the peak concentration of microbial concentrations occurs at the Ⅳ and Ⅴ levels (1.1-3.3 μm), in which the highest concentration of bacteria (253 CFU/m3) appears at the Ⅴ level, and the highest concentration of fungi (249 CFU/m3) appears at the Ⅳ level.@*Conclusion@#The microbial concentration in the air of colleges and universities was mainly concentrated in the size of 1.1-3.3 μm, and it was necessary to take targeted comprehensive control measures to effectively improve air quality.

3.
China Journal of Orthopaedics and Traumatology ; (12): 93-96, 2017.
Article in Chinese | WPRIM | ID: wpr-281339

ABSTRACT

As a common type of fracture in cervical, atlas fracture is frequently unstable due to its special anatomical structure. In a previous treatment, external fixation was likely to bring low bony union rate and long-term neck pain, while occipito-cervical fusion and atlantoaxial fusion sacrifice range of motion in cervical spine. Reduction and single section fixation of atlas by anterior lateral mass screws through the transoral approach were reported by some scholars, and the retrospective study demonstrated the high healing rate, reservation of cervical ROM and less bleeding. But it also has high risks of cervical spinal cord and vertebral artery damage, as well as the post-operation infection. Moreover, the indication and fixation strength require further evidences. As a result, this surgical option provides a new way for spinal surgeons to deal with unstable atlas fractures.